Continuous reinforcement coupler technology is important for the present and future related to structural integrity and improved design options. Now that the lapping process (which uses more steel) is on its way out, rebar couplers are proving to be cost-effective.  All types of rebar couplers transfer stress uniformly. The right approach and testing provide continuous reinforcement. With the right IS code standards the distribution is uniform.

Vruddhi Engineering Works deals with a lot more than just testing standards to achieve the best results. While supplying different products to customers, our back-end team ensures 100% tensile behavior of rebar couplers. We offer labor-friendly and economical types so that they can be implemented in any zone.

Overview

There are diverse rebar coupler designs available. They include grouted, threaded, crimped, bolted, or interlocking types. Each is designed and configured depending on the performance value it is likely to exhibit when used. They also need to undergo, tensile test, slip test, high or low cycle fatigue test.

The uniformity of the stress mechanism ensures continuous reinforcement. It matters as the size and diameter of the coupler vary to enable inter-locking mechanisms. Therefore, a strong bond plays a key role in measuring the stress levels. They are more significant when it comes to constructing advanced buildings. The stress matters for anti-seismic elements.

Typical tensile behavior

Rebar couplers have to undergo tensile behaviour and fatigue tests. This testing is essential so that the couplers meet the specifications. It is important for the vendor to carry out low cycle and high cycle fatigue tests before installations. Compliance with IS code standards ensures that the customer does not have any challenges once the project is underway.

Good tensile behaviour and stress tests are effective in connecting rebars of any length. In the construction of modern buildings, infra and residential buildings threading new rebars is a common practice. Costs are curtailed as the lapping method uses more steel. The stress transfer while threading couplers is done by captive pressure. This pressure is created between the grouted material and internal ribbed surface sleeves.

It creates the required stress uniformity.

Buyers should be aware of the engaging points to get the best deals for rebar couplers for the construction sites. It will ensure that the diameters of all rebar couplers are uniform and threaded properly. Our engineers follow the cold forging methods to make them stronger.

Typical tensile behaviour

Slip, fatigue, and tensile strengths are critical for rebar couplers to be accepted. They combine the values and give powerful results. We use specimens to conduct the tests on the coupler assembly unless a client wants it otherwise.

A slip test in rebar coupler testing measures the amount of permanent movement (slip) that occurs between the two rebar pieces joined by a coupler under tension load.

Slip Test

Low Cycle Fatigue Test

This is a cyclic load test. The specimen has to undergo a minimum of 10,000 cycles to qualify as a measure of strength. Different couplers are verified for the fatigue test.

Ultimate tensile strength

This test determines if couplers are ready to leave the factory. The mechanical splice should withstand 100 cycles of variations. There should not be any loss of static tensile strength. After the sample is tested it should remain intact.

Vruddhi Couplers has an ongoing strong commitment to its customers requiring. We provide tailor-made solutions for all infra and big construction projects. Our testing methods for stress uniformity and tensile strength make us popular with real estate developers across India.